Field	Guidance	Your entry
Specimen ID	Unique identity	
Bottle / cap / liner lots	Separate component references	
Opening history	Unopened / previously opened / other documented history	
Closing method / recipe / head	Machine input remains distinct from measured torque	
Capping timestamp	Date, time, time zone	
Test timestamp	Date, time, same time zone	
Elapsed interval	(test timestamp - capping timestamp), minutes; unknown input means unknown interval	
Conditioning / fill state	Actual conditions and method reference	
Tester / fixture	Instrument ID and gripping arrangement	
Calibration reference	Instrument record reference	
Direction / endpoint	Application, first opening peak, band break or defined later event	
Measured value	Numerical reading for that endpoint	
Unit	Instrument unit; compare like units	
Limit / unit / specification revision	Supplied package requirement; no generic limit	
Disposition	Pass / fail / invalid / unresolved against reference	
Exception / retained sample location	Observed interruption and storage reference	